Anode Carbon Dioxide Reactivity Tester
Anode Carbon Dioxide Reactivity Tester
Anode Carbon Dioxide Reactivity Tester
+
  • Anode Carbon Dioxide Reactivity Tester
  • Anode Carbon Dioxide Reactivity Tester
  • Anode Carbon Dioxide Reactivity Tester

ALC-41 Anode Carbon Dioxide Reactivity Tester is used to measure the reactivity of prebaked anode carbon blocks with carbon dioxide at specific temperature and atmosphere.
Instrument characteristics: This product meets the requirements of ISO12988-2 2004 and YS/T63.24-2012.
● Special control software and human-machine interface of high-definition touch screen can record and display real-time parameters of test time, sample number and furnace temperature. The test process is fully intelligent control. The system reserves data network transmission function to realize centralized management and real-time sharing of laboratory data.
● The rapid lifting system of the furnace cover realizes the standardization and humanization of the operation process and further improves the repeatability of experimental results.
● Porous ceramic disc and ceramic inner liner are adopted to further improve service life.
● Ceramic fiber one-time vacuum forming furnace has good vertical temperature distribution and stable constant temperature zone.
Technical parameters:

ModelALC-41
Heating power2.65KW rated voltage
Operating temperature range of reaction chamberroom temperature to 1000 ℃
Temperature rise ratefrom room temperature to 960 ℃≤ 60 min
Cooling ratetime from 960℃ to 550℃
Temperature control accuracy±1 ℃
Reactive gasHigh purity CO2
ThermocoupleK-type, measuring range 0-1100 ℃; calibration accuracy
CO2 flowmeterFull range 300L/h, accuracy 2%
CO2 pressure reducing valverange 0-1 Mpa, pressure reducing accuracy 1%
Sample size and quantityΦ50×50㎜, each reaction furnace can measure up to three samples at a time
Sample plate and bracketAlumina ceramics
Liner materialHigh temperature resistant quartz glass tube, inner diameter 168 mm, wall thickness 3 mm
Repeatability of measurementRepeatability is based on more than three test results of the same sample. The samples used in the test methods specified in ISO 12988-1200 standard and YS/T63.12-2006 standard cannot be restored after reaction, so specific values cannot be given.
Measuring reproducibilityThe sample with residual anode rate of 90% has a measurement error of less than 6%.
DimensionSingle furnace
Three furnaces1980 *550 *1630mm

Keywords

Anode Carbon Dioxide Reactivity Tester

Anode Carbon Dioxide Reactivity Tester
Anode Carbon Dioxide Reactivity Tester
Anode Carbon Dioxide Reactivity Tester
+
  • Anode Carbon Dioxide Reactivity Tester
  • Anode Carbon Dioxide Reactivity Tester
  • Anode Carbon Dioxide Reactivity Tester

Anode Carbon Dioxide Reactivity Tester

ALC-41 Anode Carbon Dioxide Reactivity Tester is used to measure the reactivity of prebaked anode carbon blocks with carbon dioxide at specific temperature and atmosphere.


Get A Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit

Online inquiry

We will contact you within one working day. Please pay attention to your email.

Online inquiry